Product Identification
Product ID:GEOSET DRILL DIAMOND (NICKEL COATED)
MSDS Date:11/12/1985
FSC:3455
NIIN:00N008760
MSDS Number: BCQYM
Responsible Party
WORTHINGTON, OH 43085
Emergency Phone: 614-438-2205
Cage: 08036
Contractor
Telephone: 614-438-2205
Cage: 08036
Ingredients
NICKEL (SARA III)
CAS: 7440-02-0
RTECS: QR5950000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
PHOSPHOROUS (YELLOW) (SARA III)
CAS: 7723-14-0
RTECS: TH3500000
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.1 MG/M3; 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
GRAPHITE, SYNTHETIC
CAS: 7440-44-0
RTECS: FF5250100
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST; 9293
COBALT (SARA III)
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: <10%
OSHA PEL 0.1 MG/M3;AS CO
ACGIH TLV: 0.05 MG/M3;DUST 9293
Hazards
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INH:POTENTIAL FOR CAUSING TRANSIENT OR
PERMANENT RESPIRATORY DISEASE (PROBABLY FROM COBALT DUST).AIRBORNE
NICKEL DUSTS ARE REGARDED AS CARCINOGENS.INGEST:IT HAS BEEN
SUGGESTED THAT COBALT HAS POTENTIA L FOR CAUSING BLOOD,HEART AND
ORGAN PROBLEMS.
Explanation of Carcinogenicity:LIMITED EVIDENCE FOR CARCINOGENICITY IN
HUMANS FOR NICKEL & SOME NICKEL COMPOUNDS (IARC 1982) (SEE SUPP
DATA)
Effects of Overexposure:INHAL:DUST FROM GRINDING CAN CAUSE THROAT &
NOSE IRRITATION.SKIN:CAN CAUSE IRRITATION OR ALLERGIC SKIN RASH DUE
TO COBALT SENSITIZATION.A FORM OF DERMATITIS CAN RESULT FROM SKIN
EXPOS TO NICKEL.EYE:CA N CAUSE IRRIT.
Medical Cond Aggravated by Exposure:N/K
First Aid
First Aid:INH:REMOVE FROM EXPOS.INGEST:IF SUSTANTIAL QUANTITIES ARE
INGESTED,DILUTE W/ LARGE AMT OF WATER.INDUCE VOMIT.SKIN:WASH W/
SOAP & WATER. EYE:FLUSH EYES W/ WATER FOR AT LEAST 15 MINUTES.FOR
ALL ABOVE CA SES,SEEK MED ATTN.
Fire Fighting
Flash Point:N/K
Extinguishing Media:N/K
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:SWEEP UP & DISPOSE INERT SOLID.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:HANDLE W/ ADEQUATE VENTILATION FOR
NUISANCE DUST.
Other Precautions:ADEQUATE EXHAUST.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN
Ventilation:LOCAL & GENERAL MECHANICAL NECESSARY TO KEEP AIR CONC BELOW
TLV
Protective Gloves:WHEN CONT W/ DUST OR MIST IS LIKELY.
Eye Protection:CHEM WORKERS GOGGLES (SEE SUPP DATA).
Other Protective Equipment:N/K
Work Hygienic Practices:N/K
Supplemental Safety and Health
EYE PROT:WEAR GOGGLES WHEN OPERATING GRINDING,CUTTING OR DRILL
EQUIP.CARCINOGENICITY:ACGIH:HUMAN CARCINOGEN (1987).PHYSICAL
PROPERTIES:BP:COATING-4892F,2700C;MP-APPROX 2552F,1400C;VP:NI-1MM @
1810C.
Chemical Properties
Boiling Pt:B.P. Text:SUPP DATA
Melt/Freeze Pt:M.P/F.P Text:SUPP DATA
Decomp Temp:Decomp Text:N/K
Vapor Pres:SUPP DATA
Solubility in Water:INSOLUBLE
Appearance and Odor:METAL COATED ARTICLES.SILVER GRAY;NO ODOR.
Percent Volatiles by Volume:NONE
Stability
Stability Indicator/Materials to Avoid:YES
N/K
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:N/K
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE W/ FEDERAL,STATE
& LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.